HDA 4400 – Relative pressure, accuracy 0.5%, industry, mobile

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 2.5…2000 bar
  • Accuracy ± 0.5% FS type; ± 1.0% FS max
  • Analogue/IO-Link/CAN
  • Options:
    • Flush membrane
    • Increased functional safety
    • Explosion-proof applications
    • Hydrogen
    • Ship
SKU
GP_1000213553
Product Search
Filter selection
Reset filter
Pressure unit
select all Reset selection
Setting range min value
select all Reset selection
Setting range max value
select all Reset selection
Accuracy [%]
select all Reset selection
Show more filters
Grouped product items
HDA 4445-B-016-000
Material no. 907299
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
16
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4445-B-600-000
Material no. 907300
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
600
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4444-A-060-000
Material no. 907319
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
60
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4444-A-250-000
Material no. 907363
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4446-A-100-000
Material no. 907989
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
100
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4445-B-040-000
Material no. 908376
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
40
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4446-A-016-000
Material no. 908483
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
16
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4446-A-400-000
Material no. 908753
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4446-B-100-000
Material no. 909045
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
100
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4446-A-250-000
Material no. 909135
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4446-B-016-000
Material no. 909197
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
16
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4446-B-250-000
Material no. 909199
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
250
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4446-B-400-000
Material no. 909431
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
400
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4446-B-600-000
Material no. 909432
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
600
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4445-A-0250-S00
Material no. 909453
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
Ship approval
Piece
HDA 4445-A-0400-S00
Material no. 909643
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
Ship approval
Piece
HDA 4445-A-160-000
Material no. 909759
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
160
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4445-A-0040-S00
Material no. 909948
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
40
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
Ship approval
Piece
HDA 4446-A-600-000
Material no. 920099
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
600
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4446-A-060-000
Material no. 920437
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
60
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 Operating instruction D/E
Operating/maintenance instructions EN

(9.75 MB)

HDA 4100/4300/4400/4700 ship Operating instructions D/E
Operating/maintenance instructions EN

(8.93 MB)

HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(10.78 MB)

HDA 4400/4700 flash membrane User manual D/E/F
Operating/maintenance instructions EN

(0.61 MB)

HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(2.51 MB)

HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.37 MB)

HDA 4400/4700 ExD HART ATEX IECEs CSA User manual D/E
Operating/maintenance instructions EN

(3.35 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(7.62 MB)

HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(6.54 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.36 MB)

HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions EN

(3.12 MB)

HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions EN

(13.04 MB)

HDA 4400 IO-Link Operating instructions D/E
Operating/maintenance instructions EN

(9.26 MB)

HDA 4400 IO-Link Quick guide D/E
Operating/maintenance instructions EN

(0.26 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.01 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.23 MB)

HDA 4400 Pressure Transmitter
Product brochure EN

(6.23 MB)

HDA 4400 Pressure Transmitter shipping applications
Product brochure EN

(5.15 MB)

HDA 4400 Pressure Transmitter Flush membrane
Product brochure EN

(3.4 MB)

HDA 4400 Pressure Transmitter Ex applications CSA Intrinsically safe for Measurement of Hydrogen
Product brochure EN

(0.21 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, CSA for Measurement of Hydrogen
Product brochure EN

(0.29 MB)

HDA 4400 IO-Link pressure transmitter
Product brochure EN

(4.43 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, CSA flashmembrane
Product brochure EN

(0.8 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure EN

(0.78 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure EN

(0.82 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure EN

(0.85 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, for themedium hydrogen, Redundant
Product brochure EN

(5.82 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, for themedium hydrogen
Product brochure EN

(3.77 MB)

HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.48 MB)

HDA 4100/4300/4400/4700 HART Ex ia CSA Standard/Flush membrane Usermanual E
Operating/maintenance instructions EN

(1.72 MB)

HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions EN

(0.74 MB)

HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions EN

(5.5 MB)

HDA 4400 Pressure Transmitter Ex application for Hydrogen SIL2 Pld
Product brochure EN

(2.17 MB)

HDA 4400/4700-CC(SC) Safety manual D/E
Operating/maintenance instructions EN

(1.17 MB)