HDA 4700 – Relative pressure, accuracy 0.25%, industry, mobile

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 2.5…2000 bar
  • Accuracy ± 0.25% FS type; ± 0.5% FS max
  • Analog/IO-Link/CAN/HART
  • Options:
    • Flush membrane
    • Increased functional safety
    • Explosion-proof applications
    • Hydrogen
    • Ship
SKU
GP_1000213555
Product Search
Filter selection
Reset filter
Pressure unit
select all Reset selection
Setting range min value
select all Reset selection
Setting range max value
select all Reset selection
Accuracy [%]
select all Reset selection
Show more filters
Grouped product items
HDA 4745-B-006-000
Material no. 907313
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
6
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4745-B-016-000
Material no. 907314
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
16
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4745-B-060-000
Material no. 907315
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
60
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4745-B-100-000
Material no. 907316
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
100
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4745-B-250-000
Material no. 907317
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
250
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Express delivery

Ready for dispatch within 48 hours of order confirmation. Express surcharge is 10% of the order value, but at least €25. Please always order express products in a separate purchase order – mixed shipping (express and regular) is not possible.

HDA 4745-B-600-000
Material no. 907318
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
600
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4774-A-0150-000(PSI)
Material no. 907345
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
150
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-0750-000(PSI)
Material no. 907346
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
750
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-1000-000(PSI)
Material no. 907347
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-1500-000(PSI)
Material no. 907348
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1500
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-3000-000(PSI)
Material no. 907349
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
3000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-5000-000(PSI)
Material no. 907350
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
5000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-6000-000(PSI)
Material no. 907351
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
6000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-A-9000-000(PSI)
Material no. 907352
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
9000
Output signal:
4 to 20mA (2 conductors)
Approvals and certificates:
UL approval
Piece
HDA 4774-B-0150-000(PSI)
Material no. 907353
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
150
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4774-B-0750-000(PSI)
Material no. 907354
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
750
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4774-B-1000-000(PSI)
Material no. 907355
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4774-B-1500-000(PSI)
Material no. 907356
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
1500
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4774-B-3000-000(PSI)
Material no. 907357
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
3000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
HDA 4774-B-5000-000(PSI)
Material no. 907358
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range min value:
0
Setting range max value:
5000
Output signal:
0 to 10V
Approvals and certificates:
UL approval
Piece
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 Operating instruction D/E
Operating/maintenance instructions EN

(9.75 MB)

HDA 4700 CANopen+SAE J1939 User manual D/E
Operating/maintenance instructions EN

(0.36 MB)

HDA 4100/4300/4400/4700 ship Operating instructions D/E
Operating/maintenance instructions EN

(8.93 MB)

HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.48 MB)

HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(10.78 MB)

HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions EN

(0.74 MB)

HDA 4400/4700 flash membrane User manual D/E/F
Operating/maintenance instructions EN

(0.61 MB)

HDA 4700/7400/7700 SAE J1939 Protocol description D/E
Operating/maintenance instructions EN

(0.24 MB)

HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(2.51 MB)

HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.37 MB)

HDA 4400/4700 ExD HART ATEX IECEs CSA User manual D/E
Operating/maintenance instructions EN

(3.35 MB)

HDA 4700 HART User manual D/E
Operating/maintenance instructions EN

(0.58 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(7.62 MB)

HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(6.54 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.36 MB)

HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions EN

(3.12 MB)

HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions EN

(13.04 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.01 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.23 MB)

HDA 4700 SAE J1939 V03 Protocol description E
Operating/maintenance instructions EN

(0.81 MB)

HDA 4700 CANopen Safety SIL3 PLe Safety manual D/E
Operating/maintenance instructions EN

(3.36 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure EN

(0.8 MB)

HDA 4700 Pressure Transmitter Ex applicationsATEX, IECEx, CSA, triple approval, HART interface
Product brochure EN

(0.86 MB)

HDA 4700 Pressure Transmitter SIL 3, PLe
Product brochure EN

(3.59 MB)

HDA 4700 Pressure Transmitter
Product brochure EN

(5.79 MB)

HDA 4700 Pressure Transmitter CAN
Product brochure EN

(4.54 MB)

HDA 4700 Pressure Transmitter shipping applications
Product brochure EN

(4.7 MB)

HDA 4700 Pressure Transmitter Ex applications, CSA approval
Product brochure EN

(0.8 MB)

HDA 4700 Pressure Transmitter PL d Cat 3
Product brochure EN

(5.09 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA
Product brochure EN

(0.87 MB)

HDA 4700 Pressure Transmitter HART
Product brochure EN

(4.52 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure EN

(0.76 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure EN

(0.91 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, Redundant
Product brochure EN

(0.82 MB)

HDA 4100/4300/4400/4700 HART Ex ia CSA Standard/Flush membrane Usermanual E
Operating/maintenance instructions EN

(1.72 MB)

HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions EN

(5.5 MB)

HDA 4700 Pressure Transmitter Ex application for Hydrogen SIL2 Pld
Product brochure EN

(2.17 MB)

HDA 4700 Pressure Transmitter Ex application SIL2 Pld
Product brochure EN

(1.08 MB)

HDA 4400/4700-CC(SC) Safety manual D/E
Operating/maintenance instructions EN

(1.17 MB)