HDA 4400 – Relative pressure, accuracy 0.5%, industry, mobile

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 2.5…2000 bar
  • Accuracy ± 0.5% FS type; ± 1.0% FS max
  • Analogue/IO-Link/CAN
  • Options:
    • Flush membrane
    • Increased functional safety
    • Explosion-proof applications
    • Hydrogen
    • Ship
Read more Show less
SKU
GP_1000213553
Product Search
Filter selection
Reset filter
Pressure unit
select all Reset selection
Setting range min value
select all Reset selection
Setting range max value
select all Reset selection
Accuracy [%]
select all Reset selection
Show more filters
Grouped product items
HDA 44G5-A-0400-EN1-H00
Material no. 927594
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 B DIN EN 837 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 44Z6-A-0250-G04-ENC-000
Material no. 927683
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 flush membrane, add. O-ring
Electrical connection:
M12x1 / 4p
Piece
HDA 44C6-A-0600-CNB-H00
Material no. 927716
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
600
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
SF250CX20 autoclave / internal
Electrical connection:
M12x1 / 4p
Piece
HDA 44Z6-A-0016-G01-000
Material no. 927773
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
16
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 flush membrane, ISO 1179-2
Electrical connection:
M12x1 / 4p
Piece
HDA 44C6-A-0600-EN9-H00
Material no. 927780
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
600
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
SF250CX20 autoclave / internal
Electrical connection:
M12x1 / 4p
Piece
HDA 44C6-A-0016-EN9-H00
Material no. 927781
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
16
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
SF250CX20 autoclave / internal
Electrical connection:
M12x1 / 4p
Piece
HDA 44GG-A-0016-DV-H00(5m)
Material no. 927856
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
16
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 B DIN EN 837 / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 44GG-A-1050-DS-H00(5m)
Material no. 927857
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1050
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 B DIN EN 837 / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 44Z6-A-0025-G01-000
Material no. 927861
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
25
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 flush membrane, ISO 1179-2
Electrical connection:
M12x1 / 4p
Piece
HDA 44G6-A-0400-EN1-H00
Material no. 927927
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
600
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 B DIN EN 837 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 44G6-A-0250-EN9-H00
Material no. 927933
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
250
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 B DIN EN 837 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 4445-A-040-000
Material no. 928159
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
40
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 A ISO 1179-2 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4446-A-040-000
Material no. 928179
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
40
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 A ISO 1179-2 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 4426-F31-1000-000
Material no. 928234
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1000
Output signal:
IO-Link
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 44C6-A-0040-EN9-H00
Material no. 928249
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
40
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
SF250CX20 autoclave / internal
Electrical connection:
M12x1 / 4p
Piece
HDA 44Z6-A-0400-G04-EN1-000
Material no. 928288
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 flush membrane, add. O-ring
Electrical connection:
M12x1 / 4p
Piece
HDA 44Z6-A-0010-G12-000
Material no. 928334
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
10
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 flush membrane, cooling section
Electrical connection:
M12x1 / 4p
Piece
HDA 44Z6-A-0016-G12-000
Material no. 928335
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
16
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 flush membrane, add. O-ring
Electrical connection:
M12x1 / 4p
Piece
HDA 4446-A-010-000
Material no. 928339
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
10
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 A ISO 1179-2 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 44G6-A-0200-EN9-H00
Material no. 928388
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
200
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 B DIN EN 837 / external
Electrical connection:
M12x1 / 4p
Piece
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 Operating instruction D/E
Operating/maintenance instructions EN

(9.75 MB)

HDA 4100/4300/4400/4700 ship Operating instructions D/E
Operating/maintenance instructions EN

(8.93 MB)

HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(10.78 MB)

HDA 4400/4700 flash membrane User manual D/E/F
Operating/maintenance instructions EN

(0.61 MB)

HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(2.51 MB)

HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.37 MB)

HDA 4400/4700 ExD HART ATEX IECEs CSA User manual D/E
Operating/maintenance instructions EN

(3.35 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(7.62 MB)

HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(6.54 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.36 MB)

HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions EN

(3.12 MB)

HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions EN

(13.04 MB)

HDA 4400 IO-Link Operating instructions D/E
Operating/maintenance instructions EN

(9.26 MB)

HDA 4400 IO-Link Quick guide D/E
Operating/maintenance instructions EN

(0.26 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.01 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.23 MB)

HDA 4400 Pressure Transmitter
Product brochure EN

(6.23 MB)

HDA 4400 Pressure Transmitter shipping applications
Product brochure EN

(5.15 MB)

HDA 4400 Pressure Transmitter Flush membrane
Product brochure EN

(3.4 MB)

HDA 4400 Pressure Transmitter for Hydrogen CSA: Intrinsically safe / Non-Incendive
Product brochure EN

(3.87 MB)

HDA 4400 Pressure Transmitter for Hydrogen ATEX, IECEx, CSA: Ex db / Ex tb
Product brochure EN

(3.41 MB)

HDA 4400 IO-Link pressure transmitter
Product brochure EN

(4.43 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, CSA flashmembrane
Product brochure EN

(0.8 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure EN

(0.78 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure EN

(0.82 MB)

HDA 4400 Pressure Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure EN

(0.85 MB)

HDA 4400 Pressure Transmitter redundant for Hydrogen ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(5.99 MB)

HDA 4400 Pressure Transmitter for Hydrogen ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(3.94 MB)

HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.48 MB)

HDA 4100/4300/4400/4700 HART Ex ia CSA Standard/Flush membrane Usermanual E
Operating/maintenance instructions EN

(1.72 MB)

HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions EN

(0.74 MB)

HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions EN

(5.5 MB)

HDA 4400 Pressure Transmitter Ex application for Hydrogen SIL2 Pld
Product brochure EN

(2.17 MB)

HDA 4400/4700-CC(SC) Safety manual D/E
Operating/maintenance instructions EN

(1.17 MB)