HDA 4700 – Relative pressure, accuracy 0.25%, industry, mobile

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 2.5…2000 bar
  • Accuracy ± 0.25% FS type; ± 0.5% FS max
  • Analog/IO-Link/CAN/HART
  • Options:
    • Flush membrane
    • Increased functional safety
    • Explosion-proof applications
    • Hydrogen
    • Ship
Read more Show less
SKU
GP_1000213555
Product Search
Filter selection
Reset filter
Pressure unit
select all Reset selection
Setting range min value
select all Reset selection
Setting range max value
select all Reset selection
Accuracy [%]
select all Reset selection
Show more filters
Grouped product items
HDA 4779-A-0300-DV-000(PSI)72inch
Material no. 922974
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
300
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
9/16-18 UNF 2A (SAE6) / external
Electrical connection:
Conduit 1/2-14 NPT single lead
Piece
HDA 4745-A-0160-AN1-000
Material no. 922978
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
160
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/4 A ISO 1179-2 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 47FG-A-0200-DV-000(psi)72inch
Material no. 923024
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
200
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-1500-DS-000(psi)72inch
Material no. 923025
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1500
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-2500-DS-000(psi)72inch
Material no. 923026
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
2500
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-3000-DS-000(psi)72inch
Material no. 923027
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
3000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-4000-DS-000(psi)72inch
Material no. 923028
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
4000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-5000-DS-000(psi)72inch
Material no. 923029
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
5000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-6000-DS-000(psi)72inch
Material no. 923030
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
6000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 47FG-A-7500-DS-000(psi)72inch
Material no. 923031
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
7500
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / internal
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-0100-DV-000(psi)72inch
Material no. 923032
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
100
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-0200-DV-000(psi)72inch
Material no. 923033
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
200
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-0500-DS-000(psi)72inch
Material no. 923034
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
500
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-1500-DS-000(psi)72inch
Material no. 923035
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1500
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-2000-DS-000(psi)72inch
Material no. 923036
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
2000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-2500-DS-000(psi)72inch
Material no. 923037
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
2500
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-3000-DS-000(psi)72inch
Material no. 923038
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
3000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-4000-DS-000(psi)72inch
Material no. 923039
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
4000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-5000-DS-000(psi)72inch
Material no. 923040
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
5000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
HDA 478G-A-6000-DS-000(psi)72inch
Material no. 923041
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
6000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
1/4-18 NPT / external
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Piece
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 Operating instruction D/E
Operating/maintenance instructions EN

(9.75 MB)

HDA 4700 CANopen+SAE J1939 User manual D/E
Operating/maintenance instructions EN

(0.36 MB)

HDA 4100/4300/4400/4700 ship Operating instructions D/E
Operating/maintenance instructions EN

(8.93 MB)

HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.48 MB)

HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(10.78 MB)

HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions EN

(0.74 MB)

HDA 4400/4700 flash membrane User manual D/E/F
Operating/maintenance instructions EN

(0.61 MB)

HDA 4700/7400/7700 SAE J1939 Protocol description D/E
Operating/maintenance instructions EN

(0.24 MB)

HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(2.51 MB)

HDA 4100/4300/4400/4700 Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.37 MB)

HDA 4400/4700 ExD HART ATEX IECEs CSA User manual D/E
Operating/maintenance instructions EN

(3.35 MB)

HDA 4700 HART User manual D/E
Operating/maintenance instructions EN

(0.58 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(7.62 MB)

HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions EN

(6.54 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions EN

(4.36 MB)

HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions EN

(3.12 MB)

HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions EN

(13.04 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.01 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions EN

(5.23 MB)

HDA 4700 SAE J1939 V03 Protocol description E
Operating/maintenance instructions EN

(0.81 MB)

HDA 4700 CANopen Safety SIL3 PLe Safety manual D/E
Operating/maintenance instructions EN

(3.36 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx
Product brochure EN

(0.8 MB)

HDA 4700 Pressure Transmitter Ex applicationsATEX, IECEx, CSA, triple approval, HART interface
Product brochure EN

(0.86 MB)

HDA 4700 Pressure Transmitter SIL 3, PLe
Product brochure EN

(3.59 MB)

HDA 4700 Pressure Transmitter
Product brochure EN

(5.79 MB)

HDA 4700 Pressure Transmitter CAN
Product brochure EN

(4.54 MB)

HDA 4700 Pressure Transmitter shipping applications
Product brochure EN

(4.7 MB)

HDA 4700 Pressure Transmitter Ex applications, CSA approval
Product brochure EN

(0.8 MB)

HDA 4700 Pressure Transmitter PL d Cat 3
Product brochure EN

(5.09 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA
Product brochure EN

(0.87 MB)

HDA 4700 Pressure Transmitter HART
Product brochure EN

(4.52 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, HART
Product brochure EN

(0.76 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, CSA, HART
Product brochure EN

(0.91 MB)

HDA 4700 Pressure Transmitter Ex applications ATEX, IECEx, Redundant
Product brochure EN

(0.82 MB)

HDA 4100/4300/4400/4700 HART Ex ia CSA Standard/Flush membrane Usermanual E
Operating/maintenance instructions EN

(1.72 MB)

HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions EN

(5.5 MB)

HDA 4700 Pressure Transmitter Ex application for Hydrogen SIL2 Pld
Product brochure EN

(2.17 MB)

HDA 4700 Pressure Transmitter Ex application SIL2 Pld
Product brochure EN

(1.08 MB)

HDA 4400/4700-CC(SC) Safety manual D/E
Operating/maintenance instructions EN

(1.17 MB)