HPT 500 – Differential pressure, accuracy 3.0%, industry, mobile

  • Hall sensor
  • Measuring range 2.0…8.0 bar
  • Accuracy +/- 3.0% FS type; +/- 5.0% FS max
  • Pressure-resistant up to 420 bar
  • Analogue/IO-Link/CAN
  • Options:
    • Explosion-proof applications
SKU
GP_1000189323
learn more ...
  • Search Bar : $SL-1000063746 [1000505463] [de]
Product Search
Filter selection
Reset filter
Express

Products with this mark can be provided within 48h - separate maximum order values may apply here. In addition, there is a surcharge of 25 euros and possibly separate freight costs

Available at short notice
Pressure unit
Select all Reset selection
Setting range max value
Select all Reset selection
Output signal
Select all Reset selection
Mechanical connection
Select all Reset selection
Show more filters

HPT 500 – Differential pressure, accuracy 3.0%, industry, mobile


Grouped product items
HPT 506-C-0030-S-000(psi)
Material-No. 925982
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 ISO 1179-2 / external
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 506-C-08.0-S-000
Material-No. 926004
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 ISO 1179-2 / external
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 506-B-05.0-S-000
Material-No. 926167
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 HN28-22
Output signal:
0 to 10V
PCE
HPT 506-C-02.0-S-000
Material-No. 926585
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 506-C-05.0-S-000
Material-No. 927145
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
Express order processing

Ready for dispatch within 48 hours after order confirmation. Express surcharge is 10% of the order value, but at least 25 €. Please always order express products in a separate order - mixed shipping (express and regular) is not possible.

HPT 506-F31-08.0-S-000
Material-No. 927734
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 HN28-22
Output signal:
IO-Link
PCE
HPT 506-F31-05.0-S-000
Material-No. 928099
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 HN28-22
Output signal:
IO-Link
PCE
HPT 506-B-02.0-S-000
Material-No. 928385
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
M12x1 / 4p
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 50K-C-08.0-S-000
Material-No. 928645
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
Deutsch DT04 / 3p
Mechanical connection:
G1/2 ISO 1179-2 / external
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 50K-C-05.0-S-000
Material-No. 929044
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
Deutsch DT04 / 3p
Mechanical connection:
G1/2 ISO 1179-2 / external
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 509-C-05.0-S-D-000(2m)
Material-No. 929090
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
ATEX, CSA, IECEx
Electrical connection:
Conduit 1/2-14 NPT single lead
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 50G-C-05.0-S-D-000(5m)
Material-No. 928857
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
ATEX, CSA, IECEx
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 50G-C-03.0-S-D-000(5m)
Material-No. 929725
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
ATEX, CSA, IECEx
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 50G-C-02.0-S-D-000(5m)
Material-No. 929726
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
ATEX, CSA, IECEx
Electrical connection:
Conduit 1/2-14 NPT sheathed cable
Mechanical connection:
G1/2 HN28-22
Output signal:
4 to 20mA (3 conductor, source)
PCE
HPT 50K-R-05.0-S-000
Material-No. 929758
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
Deutsch DT04 / 3p
Mechanical connection:
G1/2 HN28-22
Output signal:
10 to 90%UB
PCE
HPT 50K-R-08.0-S-000
Material-No. 929762
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Approval:
UL approval
Electrical connection:
Deutsch DT04 / 3p
Mechanical connection:
G1/2 HN28-22
Output signal:
10 to 90%UB
PCE

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HPT 500 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions EN

(2.96 MB)

HPT 500 User manual D/E
Operating/maintenance instructions EN

(1.4 MB)

HPT 500 CANopen User manual D/E
Operating/maintenance instructions EN

(1.18 MB)

HPT 500 IO-Link User manual D/E
Operating/maintenance instructions EN

(1.29 MB)

HPT 500 IO-Link Diff.Pressure Transmitter
Product brochure EN

(4.68 MB)

HPT 500 CAN Diff.Pressure Transmitter
Product brochure EN

(4.77 MB)

HPT 500 Diff.Pressure Transmitter Ex-Application
Product brochure EN

(10.1 MB)

HPT 500 Differential Pressure Transmitter
Product brochure EN

(4.7 MB)