HDA 4700 – Relative pressure, accuracy 0.25%, industry, mobile

  • Stainless steel measuring sensor with thin-film strain gauge
  • Measuring range 2.5…2000 bar
  • Accuracy ± 0.25% FS type; ± 0.5% FS max
  • Analog/IO-Link/CAN/HART
  • PSI devices on request
  • Options:
    • Flush membrane
    • Increased Functional Safety
    • Explosion-proof applications
    • Hydrogen
    • Ship
Read more Show less
SKU
GP_1000213555
Product Search
Filter selection
Reset filter
Pressure unit
select all Reset selection
Setting range min value
select all Reset selection
Setting range max value
select all Reset selection
Accuracy [%]
select all Reset selection
Show more filters
Grouped product items
HDA 44Z6-F31-0004-G02-000(-1..+1bar)
Material no. 931076
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1
Output signal:
IO-Link
Mechanical connection:
G1/2 flush membrane, add. O-ring
Electrical connection:
M12x1 / 4p
Piece
HDA 4715-A-025-000
Material no. 923005
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
25
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4715-A-160-000
Material no. 923724
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
160
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4715-A-1600-000
Material no. 931121
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1600
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4715-A-2000-000
Material no. 928029
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
2000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4715-A-400-000
Material no. 909791
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
400
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4716-A-1600-000
Material no. 924411
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1600
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 4716-A-2000-000
Material no. 927213
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
2000
Output signal:
4 to 20mA (2 conductors)
Mechanical connection:
G1/2 B DIN EN 837 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 4725-F21-0100-T-007-000
Material no. 927176
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
100
Output signal:
4 to 20mA (2 conductors), HART
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
DIN EN 175301-803 /3p + PE
Piece
HDA 4726-F21-0400-T-007-EN1-000
Material no. 928552
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
400
Output signal:
HART
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 4p
Piece
HDA 4728-F11-0016-T-007-000
Material no. 930863
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
16
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-0040-T-007-000
Material no. 927505
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
40
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-0100-T-007-000
Material no. 927504
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
100
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-0250-T-007-000
Material no. 926872
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
250
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-0400-T-007-000
Material no. 921235
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
400
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-0600-000
Material no. 921810
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
600
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-0600-T-007-000
Material no. 927503
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
600
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F11-1000-000
Material no. 926358
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
1000
Output signal:
CANopen
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4728-F12-0250-T-007-000
Material no. 929728
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
250
Output signal:
CAN J1939
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
M12x1 / 5p
Piece
HDA 4729-F21-0100-T-007-DS-000(2m)
Material no. 925785
Deliverable within ca. - days Request replacement time loading... The replacement time depends on the product quantity.
Setting range max value:
100
Output signal:
HART
Mechanical connection:
G1/2 ISO 1179-2 / external
Electrical connection:
Conduit 1/2-14 NPT single lead
Piece
Page

Downloads

CAD data can’t be found at the product category level. Instead, it can be found directly at an individual product level.
Media
HDA 4400/4700 Operating instruction D/E
Operating/maintenance instructions DE, EN

(9.75 MB)

HDA 4700 CANopen+SAE J1939 Operating instructions D/E
Operating/maintenance instructions DE, EN

(4.14 MB)

HDA 4100/4300/4400/4700 ship Operating instructions D/E
Operating/maintenance instructions DE, EN

(8.93 MB)

HDA 4100/4300/4400/4700 Ex ia CSA User manual E
Operating/maintenance instructions EN

(1.48 MB)

HDA 4400/4700 ExD ATEX IECEx CSA User manual D/E
Operating/maintenance instructions DE, EN

(10.78 MB)

HDA 4400/4700-CC Analogue Safety Safety manual D/E
Operating/maintenance instructions DE, EN

(0 MB)

HDA 4400/4700 flash membrane Operating instructions D/E
Operating/maintenance instructions DE, EN, FR

(8.77 MB)

HDA 4700/7400/7700 SAE J1939 Protocol description D/E
Operating/maintenance instructions DE, EN

(0 MB)

HDA 4100/4300/4400/4700 HART Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions DE, EN

(2.51 MB)

HDA 4100/4300/4400/4700 Ex ia ATEX IECEx Standard/Flush membrane Usermanual D/E
Operating/maintenance instructions DE, EN

(4.37 MB)

HDA 4400/4700 ExD HART ATEX IECEs CSA Standard/Flush membrane Usermanual D/E
Operating/maintenance instructions DE, EN

(3.35 MB)

HDA 4700 HART Operating instructions D/E
Operating/maintenance instructions DE, EN

(4.12 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions DE, EN

(7.62 MB)

HDA 4400/4700 Ex ia ATEX IECEx for H2 User manual D/E
Operating/maintenance instructions DE, EN

(6.54 MB)

HDA 4400/4700-AA Ex ia ATEX IECEx User manual D/E
Operating/maintenance instructions DE, EN

(4.36 MB)

HDA 4400/4700 Ex ia CSA for H2 User manual E
Operating/maintenance instructions EN

(3.12 MB)

HDA 4400/4700 ExD ATEX IECEx CSA für H2 User manual D/E
Operating/maintenance instructions DE, EN

(13.04 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx User manual+Safety manual D/E
Operating/maintenance instructions DE, EN

(5.01 MB)

HDA 4400/4700-A Ex ia SIL2 PLd ATEX IECEx for H2 User manual+Safety manual D/E
Operating/maintenance instructions DE, EN

(5.23 MB)

HDA 4700 SAE J1939 V03 Protocol description E
Operating/maintenance instructions EN

(0 MB)

HDA 4700 CANopen Safety SIL3 PLe Safety manual D/E
Operating/maintenance instructions DE, EN

(3.36 MB)

HDA 4700 Pressure Transmitter ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(0 MB)

HDA 4700 HART Pressure Transmitter with Junction Box ATEX, IECEx, CSA: Ex db / Ex tb
Product brochure EN

(0 MB)

HDA 4700 CANopen Safety Pressure Transmitter SIL 3 / PLe Cat.3
Product brochure EN

(3.59 MB)

HDA 4700 Pressure Transmitter
Product brochure EN

(5.79 MB)

HDA 4700 CANopen, SAE J1939 Pressure Transmitter
Product brochure EN

(4.49 MB)

HDA 4700 Pressure Transmitter Ship applications
Product brochure EN

(4.7 MB)

HDA 4700 Pressure Transmitter CSA: Intrinsically safe / Non-Incendive
Product brochure EN

(0 MB)

HDA 4700 Pressure Transmitter redundant PLd Cat.3
Product brochure EN

(5.09 MB)

HDA 4700 Pressure Transmitter ATEX, IECEx, CSA: Ex db, Ex tb
Product brochure EN

(0 MB)

HDA 4700 HART Pressure Transmitter
Product brochure EN

(4.47 MB)

HDA 4700 HART Pressure Transmitter ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(0 MB)

HDA 4700 HART Pressure Transmitter ATEX, IECEx, CSA: Ex db / Ex tb
Product brochure EN

(0 MB)

HDA 4700 Pressure Transmitter redundant ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(0 MB)

HDA 4100/4300/4400/4700 HART Ex ia CSA Standard/Flush membrane Usermanual E
Operating/maintenance instructions EN

(1.72 MB)

HDA 4400/4700 CANopen Safety SIL3 PLe Protocol description E
Operating/maintenance instructions EN

(5.5 MB)

HDA 4700 Pressure Transmitter for Hydrogen ATEX, IECEx: Ex ia / Ex ec, SIL 2 / PLd
Product brochure EN

(2.17 MB)

HDA 4700 Pressure Transmitter ATEX, IECEx: Ex ia / Ex ec, SIL 2 / PLd
Product brochure EN

(1.08 MB)

HDA 4400/4700-CC(SC) Safety manual D/E
Operating/maintenance instructions DE, EN

(1.17 MB)

Electronic Pressure Transmitter HDA 4700 with Flush Membrane
Product brochure EN

(0.84 MB)

HDA 4700 Pressure Transmitter redundant for Hydrogen ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(5.99 MB)

HDA 4700 Pressure Transmitter for Hydrogen ATEX, IECEx: Ex ia / Ex nA / Ex ta
Product brochure EN

(3.94 MB)

HDA 4700 Pressure Transmitter for Hydrogen CSA: Intrinsically safe / Non-Incendive
Product brochure EN

(3.87 MB)

HDA 4700 Pressure Transmitter for Hydrogen ATEX, IECEx, CSA: Ex db / Ex tb
Product brochure EN

(3.42 MB)